Molift Air Ceiling Hoists
Molift Air is an innovative and functional ceiling lift for all types of users. Combined with Etacs rail system: Molift Rail System, Molift Air handles all lifting situations within the care sector. Molift Air ceiling lifts are offered with max. lifting capacities from 200 kg all the way up to 500 kg.
Classification
12 36 12 02 - Stationary hoists fixed to walls, floor or ceiling
Documents
Video
The product series includes 14 products of which 1 product is discontinued.
Specifications summarized
Specifications for the 14 products in the product series. Click a HMI-no. to see all details for a single product.Product 1 - 10 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Specification/HMI-no. | 84693 discont. | 84697 | 84699 | 84695 | 84694 | 84698 | 84700 | 84696 | 128723 | 122611 |
Electrical lifting mechanism | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Electrical horizontal movement | No | No | Yes | No | No | No | Yes | No | Yes | No |
Intended fixation to ceiling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to wall(s) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Intended fixation to floor | No | No | No | No | No | No | No | No | No | No |
Fitted with seat | No | No | No | No | No | No | No | No | No | No |
Intended use for swimming pools | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Room covering rail system | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Door transition without manual handling | No | No | No | No | No | No | No | No | No | No |
Door transition with manual handling | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Detachable lifting machinery | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
External battery charger | Yes | No | No | Yes | Yes | No | No | Yes | No | Yes |
Charging station at track | No | Yes | Yes | No | No | Yes | Yes | No | Yes | No |
Charging liner | No | Yes | Yes | No | No | Yes | Yes | No | Yes | No |
Emergency lowering function, electrically operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Emergency lowering function, manually operated | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
User weight, max (kg) | 205 | 205 | 205 | 205 | 300 | 300 | 300 | 300 | 350 | 350 |
Max lifting velocity, loaded (m/s) | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.06 |
Weight of lifting machinery (kg) | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 8.6 |
Min. distance from ceiling to central suspension point (cm) | 55.2 | 55.2 | 55.2 | 55.2 | 55.2 | 55.2 | 55.2 | 55.2 | 55.2 | 48.7 |
Ingress protection class for water (IP) | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
Maintenance frequency (måneder) | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
Product 11 - 14 | ||||
---|---|---|---|---|
Specification/HMI-no. | 122610 | 129404 | 115176 | 119220 |
Electrical lifting mechanism | Yes | Yes | Yes | Yes |
Electrical horizontal movement | No | No | No | No |
Intended fixation to ceiling | Yes | Yes | Yes | Yes |
Intended fixation to wall(s) | Yes | Yes | Yes | Yes |
Intended fixation to floor | No | No | No | No |
Fitted with seat | No | No | No | No |
Intended use for swimming pools | Yes | Yes | Yes | Yes |
Room covering rail system | Yes | Yes | Yes | Yes |
Door transition without manual handling | No | No | No | No |
Door transition with manual handling | Yes | Yes | Yes | Yes |
Detachable lifting machinery | Yes | Yes | Yes | Yes |
External battery charger | Yes | Yes | Yes | Yes |
Charging station at track | No | No | No | No |
Charging liner | No | No | No | No |
Emergency lowering function, electrically operated | Yes | Yes | Yes | Yes |
Emergency lowering function, manually operated | Yes | Yes | Yes | Yes |
User weight, max (kg) | 350 | 500 | 200 | 200 |
Max lifting velocity, loaded (m/s) | 0.06 | 0.35 | 0.6 | 0.6 |
Weight of lifting machinery (kg) | 8.6 | 7.5 | 8.56 | 8.56 |
Min. distance from ceiling to central suspension point (cm) | 48.7 | 55.2 | 44.7 | 44.7 |
Ingress protection class for water (IP) | 4 | 4 | 4 | 4 |
Maintenance frequency (måneder) | 12 | 12 | 12 | 12 |